Used in solar energy, Type 1, maximum operating voltage includes 750Vdc, 1200Vdc, 1500Vdc, nominal discharge current (8/20µs) In is 20kA, maximum discharge current impulse current Imax is 40kA, (10/350µs) Iimp is 12.5kA, total impulse current (10/350 µs) Itotal 25kA, 2-pole.
                        Contact Us
                      
                  
                  Used in energy storage, maximum operating voltage is DC1200, nominal discharge current is 15kA, maximum discharge current is 40kA.
                        Contact Us
                      
                  
                  Used in energy storage, maximum operating voltage is DC1200, nominal discharge current is 15kA, maximum discharge current is 40kA.
                        Contact Us
                      
                  
                  Used in telecom, operating voltage is AC120V-AC400V, nominal discharge current is 20kA, maximum discharge is 40kA.
                        Contact Us
                      
                  
                  Used in solar energy, nominal discharge current (In) is 20kA, max. discharge current (Imax) is 50 kA,and impulse current by pole (Iimp) is 12.5kA.
                        Contact Us
                      
                  
                  Used in the solar energy and energy storage,operating voltage is DC1500, nominal discharge current is 20kA, max. discharge current is 40kA.
                        Contact Us
                      
                  
                  Used in the solar energy ,operating voltage is DC600V, nominal discharge current is 20kA, max. discharge current is 40kA.
                        Contact Us
                      
                  
                  Used in the solar energy ,operating voltage is DC670V, nominal discharge current is 10kA, max. discharge current is 20kA.
                        Contact Us
                      
                  
                  Used in the solar energy ,operating voltage is DC320V, nominal discharge current is 25kA,and the voltage protection level is 1.8kV.
                        Contact Us
                      
                  
                  Surge Protective Device for solar energy.The working voltage including AC275V,AC320V,AC385V,AC440V,AC550V,DC600V,DC1000V.
                        Contact Us
                      
                  
                  Surge Protective Device for solar energy.The working voltage including DC600V,DC1000V,lmax(8/20us):40kA.
                        Contact Us
                      
                  
                  Used in wind energy and energy storage, maximum operating voltage is AC760, nominal discharge current is 35kA, maximum discharge current is 70kA, and impulse current by pole (Iimp) is 25kA.
                        Contact Us
                      
                  
                  Used in wind energy , maximum operating voltage is AC1100, nominal discharge current is 20kA, maximum discharge current is 40kA.
                        Contact Us
                      
                  
                  Used in wind energy , maximum operating voltage is AC1000, nominal discharge current is 15kA, maximum discharge current is 30kA.
                        Contact Us
                      
                  
                  Used in the wind energy, operating voltage is AC120V-AC400V, nominal discharge current is 20kA, maximum discharge is 50kA.
                        Contact Us
                      
                  
                  Used in the wind energy and energy storage, operating voltage is AC120V-AC400V, nominal discharge current (15 x 8/20 µs impulses) In is 20 kA, maximum discharge is 50kA,and total maximum discharge current (max. total withstand @ 8/20 µs )is 50kA.
                        Contact Us
                      
                  
                  Used in wind energy, nominal DC voltage is DC24V, nominal discharge current is 1.5kA, maximum discharge is 3kA.
                        Contact Us
                      
                  
                  Used in the wind energy and energy storage ,operating voltage is DC385V, nominal discharge current is 20kA, max. discharge current is 40kA.
                        Contact Us
                      
                  
                  Used in the wind energy ,operating voltage is DC30V, nominal discharge current is 1kA.
                        Contact Us
                      
                  
                  Used in wind energy, nominal Voltage is 24V,Max. continuous operating voltage is DC23V,Max. continuous operating voltage is AC23.3V.