Used in solar energy, the working voltage included AC800V, Icu=60kA; AC1000V, Icu=55kA; AC1140V, Icu=50kA, AC1380V, Icu=50kA, AC1500V, Icu=50kA, frame current is 2500A and the rated current ranging from 630A to 2500A.


Used in solar energy, the working voltage included AC800V, Icu=75kA; AC1000V, Icu=75kA; AC1140V, Icu=75kA, frame current is 4000A and the rated current ranging from 800A to 4000A.


Used in solar energy, the working voltage included AC800V, Icu=85kA; AC1000V, Icu=66kA; AC1140V, Icu=66kA, frame current is 6300A and the rated current ranging from 4000A to 6300A.


Used in solar energy, the working voltage included AC220V,AC230V,AC240V,AC380V,AC400V(Icu=100kA),AC415V,AC440V,AC480V,AC660V,AC690V(Icu=75kA),AC800V(Icu=70kA),AC1000V/AC1140V(Icu=55kA), frame current is 4000A and the rated current ranging from 800A to 4000A.


Used in solar energy, the working voltage included AC220V,AC230V,AC240V,AC380V,AC400V(Icu=120kA),AC415V,AC440V,AC480V,AC660V,AC690V(Icu=85kA),AC800V(Icu=75kA),AC1000V/AC1140V(Icu=60kA), frame current is 6300A and the rated current ranging from 4000A to 6300A.


Used in wind energy, the working voltage included AC415V, Icu=100kA; AC690V, Icu=75kA, frame current is 3200A and the rated current ranging from 2000A to 3200A.


Used in wind energy, the working voltage included AC415V, Icu=100kA; AC690V, Icu=75kA, frame current is 3200A and the rated current ranging from 2000A to 4000A.


Used in wind energy, the working voltage included AC415V, Icu=100kA; AC690V, Icu=75kA, frame current is 3200A and the rated current ranging from 4000A to 6300A.


Used in wind energy, the working voltage included AC400V, Icu=100kA; AC690V, Icu=75kA; AC800V, Icu=70kA; AC1000V, Icu=55kA; AC1140V, Icu=55kA, frame current is 4000A and the rated current ranging from 800A to 4000A.


Used in wind energy, the working voltage included AC400V, Icu=120kA; AC690V, Icu=85kA; AC800V, Icu=75kA; AC1000V, Icu=60kA; AC1140V, Icu=60kA, frame current is 6300A and the rated current ranging from 4000A to 6300A.


Used in wind energy, S:the working voltage included AC220V~415V, Icu=66kA; AC440V/480V/660V/690V, Icu=55kA; H:the working voltage included AC220V~415V, Icu=85kA; AC440V/480V/660V/690V, Icu=66kA, XU:the working voltage included AC1140V/1380V/1500V,Icu=50kA,frame current is 2500A and the rated current ranging from 630A to 2500A.


Used in wind energy, S:the working voltage included AC220V~400V, Icu=85kA; AC415V/440V/480V/660V/690V,Icu=75kA;H:the working voltage included AC220V~400V, Icu=100kA; AC415V/440V/480V/660V/690V, Icu=85kA, XU:the working voltage included AC1140V ,Icu=85kA ;AC1380V/1500V,Icu=50kA,frame current is 4000A and the rated current ranging from 800A to 4000A.


Used in wind energy, S:the working voltage included AC220V~415V, Icu=120kA; AC440V/480V/660V/690V, Icu=85kA; H:the working voltage included AC220V~415V, Icu=135kA; AC440V/480V/660V/690V, Icu=100kA, XU:the working voltage included AC1140V/1380V/1500V,Icu=80kA,frame current is 6300A and the rated current ranging from 4000A to 6300A.


Used in wind energy, S:the working voltage included AC220V~415V, Icu=150kA; AC440V/480V/660V/690V, Icu=100kA; H:the working voltage included AC220V~415V, Icu=160kA; AC440V/480V/660V/690V, Icu=120kA, frame current is 7500A and the rated current ranging from 4000A to 7500A.


Used in energy storage, the working voltage included DC1250V;DC1500V, Icm=125kA, frame current is 2500A and the rated current ranging from 1600A to 2500A.